{"created":"2023-06-20T13:20:30.454018+00:00","id":534,"links":{},"metadata":{"_buckets":{"deposit":"95493f26-00e9-47fd-9e01-ffe17e1206d9"},"_deposit":{"created_by":1,"id":"534","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"534"},"status":"published"},"_oai":{"id":"oai:ir.soken.ac.jp:00000534","sets":["2:427:12"]},"author_link":["0","0","0"],"item_1_creator_2":{"attribute_name":"著者名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"VESHCHEV, EVGENY"}],"nameIdentifiers":[{}]}]},"item_1_creator_3":{"attribute_name":"フリガナ","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ヴェシュチェフ, エヴェグニ"}],"nameIdentifiers":[{}]}]},"item_1_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2007-09-28"}]},"item_1_degree_grantor_5":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"総合研究大学院大学"}]}]},"item_1_degree_name_6":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(学術)"}]},"item_1_description_12":{"attribute_name":"要旨","attribute_value_mlt":[{"subitem_description":"   Analysis of energy-resolved spectra of neutral particles escaped from plasma can provide important knowledge about ion confinement and ion distribution function during different types of plasma heating such as neutral beam injection (NBI), ion cyclotron heating (ICH) or electron cyclotron heating (ECH). Such knowledge is very important for the successful development of a fusion reactor. Effective ion heating and good fast ion confinement are essential for ignition. Compared with tokamaks, studying the fast particle confinement properties in heliotrons is more complex mainly due to more complex magnetic configuration. Such a complex 3D geometry of the Large Helical Device (LHD) may lead to appearance of additional types of confined particles (such as helically trapped particles), additional confinement effects (presence of loss-cones) and may result in more complicated drift motions. For studying fast ion confinement properties in plasma, a variety of neutral particle analyzing diagnostics have been developed on modern fusion devices. In LHD these are one-chord Compact Neutral Particle Analyzer (CNPA) and six-chord Silicon-Detector NPA (SDNPA), etc. E∥B type CNPA utilizes one array of 40 detectors and measures energy and time resolved neutral particle fluxes in the energy range 1-170 keV. CNPA can be used in a combination with Tracer Encapsulated Solid Pellet (TESPEL) injector. Sightline of CNPA is very close to the nominal TESPEL trajectory, and thus active localized measurements can be made by the pellet charge exchange method. SDNPA can provide the measurements in the energy range 25-4000 keV and the aim of it is to make angle-resolved passive measurements of fast particles.
   According to some theoretical estimations, in heliotron devices the transition particles may be lost from the confinement region through loss cones. The loss cones of fast particles in LHD plasmas could not be measured so far by the existing diagnostics mainly due to the poor angular resolution (to make angle resolved measurements either a long time discharge or several shots with exactly similar parameters are required). To clarify the situation with loss-cones and to improve the angular resolution versus the existing SDNPA analyzer, a novel diagnostic with a much better angular resolution is required. The overview of currently used NPA diagnostics in tokamaks and heliotrons will be made in the Introductory chapter I . Among the preceding multi-sightline NPA systems used in magnetic confinement fusion devices the maximum sightline NPA systems with 6 chords of view are on LHD (currently operating SDNPA) and on former TFTR (discontinued). Thus a novel 20-sightline diagnostic based on an Angular Resolved Multi-Sightline NPA (ARMS-NPA) described in this thesis may become a new powerfu1 tool in fast ion physics studies. It can provide energy-, angle-, and time-resolved spectra of escaped fast neutral particles from the plasma. In addition, a precise radial scan of the plasma column can be realized. The data obtained by this new ARMS-NPA diagnostic in addition to CNPA and SDNPA experiments will help in understanding of fast particle physics in helical systems.
   First measurements by ARMS-NPA diagnostic have been made on LHD for a variety of plasma heating conditions. Angularly resolved measurements were made for co-, counter- and perpendicularly directed NBI, for ICRH and ECH regimes. Measurements were made for a wide range of plasma parameters such as electron density, magnetic axis position, positive and negative magnetic field directions, and magnetic field strength. Obtained data demonstrate angular dependence of fast particle distribution for the type of heating and plasma parameters. Magnetic axis shift effect on loss-cones has been noticed. Inward shifted magnetic axis configuration lead to improved fast ion confinement and uniform angular distribution (reduction of the loss-cone). Since the naturally occurring charge exchange neutral particle source is not localized in contrast to the diagnostic neutral beam or pellet charge exchange methods, the correct interpretation of such measurements in a complex toroidal asymmetric geometry requires a careful numerical modeling of the neutral flux formation and the knowledge of the charge-exchange target distributions, relevant cross sections and the magnetic surface structure. The measured chord integral neutral flux calculation scheme for the LHD magnetic surface geometry is given. Calculation results are shown for measurable atomic energy spectra corresponding to heating-induced fast ion distributions from simplified Fokker-Planck models. The behavior of calculated and experimental suprathermal particle distributions in NBI and ICRF heated plasmas is discussed in the context of the experimenta1 data interpretation. The geometry effect on the measured spectra interpretation is discussed. Results of experimental measurements are also compared with simulation results made by different codes with taking fast particle orbits into account.","subitem_description_type":"Other"}]},"item_1_description_7":{"attribute_name":"学位記番号","attribute_value_mlt":[{"subitem_description":"総研大甲第1088号","subitem_description_type":"Other"}]},"item_1_select_14":{"attribute_name":"所蔵","attribute_value_mlt":[{"subitem_select_item":"有"}]},"item_1_select_8":{"attribute_name":"研究科","attribute_value_mlt":[{"subitem_select_item":"物理科学研究科"}]},"item_1_select_9":{"attribute_name":"専攻","attribute_value_mlt":[{"subitem_select_item":"10 核融合科学専攻"}]},"item_1_text_10":{"attribute_name":"学位授与年度","attribute_value_mlt":[{"subitem_text_value":"2007"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"VESHCHEV, Evgeny","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-17"}],"displaytype":"simple","filename":"甲1088_要旨.pdf","filesize":[{"value":"323.9 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"要旨・審査要旨","url":"https://ir.soken.ac.jp/record/534/files/甲1088_要旨.pdf"},"version_id":"4309a7d1-89f1-4032-8995-252ea4514fa5"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-02-17"}],"displaytype":"simple","filename":"甲1088_本文.pdf","filesize":[{"value":"14.0 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"本文","url":"https://ir.soken.ac.jp/record/534/files/甲1088_本文.pdf"},"version_id":"98715d63-9629-4485-a599-9c77c2ea5085"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"thesis","resourceuri":"http://purl.org/coar/resource_type/c_46ec"}]},"item_title":"Devlopment of Fast Neutral Particle Diagnostics and Study of Suprathermal Ion Behaviors in LHD Plasmas","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Devlopment of Fast Neutral Particle Diagnostics and Study of Suprathermal Ion Behaviors in LHD Plasmas"},{"subitem_title":"Devlopment of Fast Neutral Particle Diagnostics and Study of Suprathermal Ion Behaviors in LHD Plasmas","subitem_title_language":"en"}]},"item_type_id":"1","owner":"1","path":["12"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-02-22"},"publish_date":"2010-02-22","publish_status":"0","recid":"534","relation_version_is_last":true,"title":["Devlopment of Fast Neutral Particle Diagnostics and Study of Suprathermal Ion Behaviors in LHD Plasmas"],"weko_creator_id":"1","weko_shared_id":1},"updated":"2023-06-20T16:01:27.556077+00:00"}